| | | | Va | ue | |
| Symbol | Parameter | Test conditions | Tj=250C | = 1250C | Unit |
| Typ. | Max | Typ. | Max |
| VF+ | Forward voltage drop | IF=6A | 1.4 | 2.2 | 1.2 | 1.65 | V |
| IR | Reverse leakage current | VR=1500V | | 1 00 | 1 00 | 1 000 | |
| | | | | | | |
Power-Saving Features When configured as OE, the general-purpose input three-states all outputs when pulled LOW. When configured as Shutdown, a LOW on this pin three-states all outputs and shuts off the PLLs, counters, the reference oscillator, and all other active components. The resulting current on the VDD pins will be less than 5 UA (typical). After leaving shutdown mode. the PLLs will have to relock.