| | | | Ratings | |
| Parameter | Symbol | Conditions | min | typ | max | Unit |
| Output limiter withstand voltage | VOLM1 | Z1, 22 0pen | 54 | 57 | 60 | V |
| VOLM2 | Z1, 22 short | 31 | 33 | 35 | V |
| Output saturation voltage | Vosatl 2 | lo = 0.5A lo = 1.OA | | O95 0.15 | 1.2 1.5 | V V |
| VIN voltage | VIN | ICC= 7.0 mA | 6 4 | 6 7 | 7O | V |
| Hall input sensitivity (at zero peak) | VHN | Including offset and hysteresis | | | 20 | mV |
| RD output saturation voltage | VRDsat | IRD=5mA | | 0 1 | 0.3 | V |
| CT drain current | IC1 | C= GND | 2 7 | 3 8 | 4.9 | A |
| CT discharge current | IC2 | C= VIN | O19 | 0.30 | 0 41 | |
| Comp input threshold voltage | VTH1 VTH2 | | 0.77 0 42 | 0.8VIN 0.45VIN | 0 83 0 48 | V V |
| Thermal protection operating temperature | TSD | Design target value* | | 180 | | IC |
| Thermal protection circuit hysteresis | TSD | Design target value* | | 40 | | Ic |
| | | | | | |
. T1-Related Telecommunications Specifications . ANSI Tl.102- Digital Hierarchy Electrical Interface . ANSI Tl.231- Digital Hierarchy- Layer l in Service Performance Monitoring . ANSI Tl.403- Network and Customer Installation Interface- DSl Electrical Interface * G.736 Characteristics of a synchronous digital multiplex equipment operating at 2048 kbit/s . G.823 The control of jitter and wander within digital networks which are based on the 2048 kbit/s hierarchy . Pub 62411 High Capacity Terrestrial Digital Service * ITUT G.772 Protected monitoring points provided on digital transmission systems