ADMap-16  > QM40-14PAL-PR

suppliers of QM40-14PAL-PR and PDF data of QM40-14PAL-PR

Part Numbert Mfg Packt D/C Descriptiont Qty Company/Contact  

QM40-14PAL-PR Datasheet

75 100 2.5 5 12 14 20 40 0.1 0.25 0.4 0.5 0.6 1.0 400 1200 2500 3000 4500 6500
95 120 3 6 15 18 25 50 0.1 0.25 0.4 0.5 0.6 1.0 400 1200 2500 3000 4500 6500
115 150 3.5 8 18 22 30 60 0.1 0.25 0.4 0.5 0.6 1.0 400 1200 2500 3000 4500 6500
135 175 4.5 10 21 25 40 75 0.1 0.25 0.4 0.5 0.6 1.0 400 1200 2500 3000 4500 6500
130 175 72 1.0 6500
140 180 4.5 10 23 26 40 75 0.1 0.25 0.4 0.5 0.6 1.0 400 1200 2500 3000 4500 6500
150 200 5 11 25 28 45 80 0.1 0.25 0.4 0.5 0.6 1.0 400 1200 2500 3000 4500 6500
150 200 80 1.0 65
160 205 5 11 25 30 45 80 O.l 0.25 0.4 0.5 0.6 1.0 400 1200 2500 3000 4500 6500
170 225 6 12 30 32 50 90 0.1 0.25 0.4 0.5 0.6 1.0 400 1200 2500 3000 4500 6500


QM40-14PAL-PR Price

Frequency Z Source Z Load
MHz R jx R jx
470 2.0 -3.6 9.8 -9.8
650 3.6 -7.0 9.0 -1.3
860 6.0 -13.5 4.5 -5.0


QM40-14PAL-PR on stock

f r
T J=I 15'C r j
f l
J J
l | I Tj 25 'c
I
f I
f f


Premier Devices reserves the right to make changes without further notice to any products herein. Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. "Typical" parameters which may be provided in Premier Devices datasheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including "Typicals" must be validated for each customer application by customer's technical experts. Premier Devices does not convey any license under its patent rights nor the rights of others. Premier Devices products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life or for any other application in which the failure of the Premier Devices product could create a situation where personal injury or death may occur. Should Buyer purchase or use Premier Devices products for any such unintended or unauthorized application, Buyer shall indemnify and hold Premier Devices and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, and claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part.