| Part Numbert | Mfg | Packt | D/C | Descriptiont | Qty | Company/Contact | |
| N1030B | APM HEXSEAL | 08+ | Stock on hand | 30000 |
|
![]()
|
N1030B Datasheet
N1030B Price
N1030B on stock After each 24-hour period has elapsed, the battery is connected to an internal lMQ test resistor for one second. During this one second, if battery voltage falls below the battery voltage trip point (2.6V), the battery warning output BW iS asserted. Once asserted, BW remains active until the module is replaced. The battery is still retested after each Vcc power-up, however, even if BW iS active. If the battery voltage is found to be higher than 2.6V during such testing, BW iS de-asserted and regular 24-hour testing resumes. BW has an open drain output driver. - Over-temperature warning - Battery monitoring to detect battery interrupt or a chattering battery contact to store data before microcontroller power down (e.g. to store seat position) - Signalling of potential RAM-retention errors due to low microcontroller Vcc. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||