(3) The products described in this material are intended to be used for standard applications or gen- eral electronic equipment (such as office equipment, communications equipment, measuring in- struments and household appliances). Consult our sales staff in advance for information on the following applications: . Special applications (such as for airplanes, aerospace, automobiles, traffic control equipment, combustion equipment, life support systems and safety devices) in which exceptional quality and reliability are required, or if the failure or malfunction of the products may directly jeopardize life or harm the human body. . Any applications other than the standard applications intended.
| Symbol | Parameter | Reference Test Method | Min | Max | Units |
| NEND(s) | ndu rance | MIL-STD-883, Test Method 1033 | 1,000.000 | | Cycles/Byte |
| TDR(s) | Data Retention | MIL-STD-883, Test Method 1008 | 1 00 | | Years |
| VZAp(5) | ESD Susceptibility | MIL-STD-883, Test Method 3015 | 2000 | | Volts |
| ILTH(5)(7) | Latch-Up | JEDEC Standard 17 | 1 00 | | mA |
| | | | | |
Rx FIFO Status: These bits (D5 and D4) indicate the status of receive FIFO as given by Table 4. The Rx FIFO status bits are not updated immediately after an access of the Rx FIFO (a read from the microprocessor port, or a write from the serial port), to avoid the existence of unrecoverable error conditions.